Server Name | Version | Category | OS | OS Subclass | Publish Date | Operate | |
HBA-LSI-9300-8i | 40.00.00.00 | Driver | linux | CAS-E0783 | 2024/8/22 |
|
|
Version
40.00.00.00
File Name
Linux Driver Release Notes.pdf(454.94 KB) driver-storage-broadcom-IT-IR-40.00.00.00 CAS-E0783.zip(166.85 KB)
Description
The software is the driver of broadcom IT-IR storage controller card in the Linux operating system (OS).
Problems Solved
1.Increase the device scanning scsi command timeout event to 30 seconds to address the issue where certain SATA drives require more time to process the device scanning scsi command after adding PUIS (Power Up in Standby) functionality via HBA firmware, resulting in initialization and detection failures in the operating system. 2.Fixed compilation errors occurring on kernel versions 5.12 to 5.15. 3.Fixed the issue causing system crashes due to use-after-free triggered by executing rmmod and related operations. Refer to the following log information for more details: 
Products
- H3C UniServer R4900 G5
- H3C UniServer R4500 G3
- H3C UniServer R5300 G3
- H3C UniServer R4500 G6
- H3C UniServer R4950 G5 Milan
- H3C UniServer R4900 G6
- H3C UniServer R5350 G6
- H3C UniServer R6900 G5
- H3C UniServer R4300 G3
- H3C UniServer R4900 G6 Ultra
- H3C UniServer R2900 G3
- H3C UniServer R6900 G6
- H3C UniServer R5500 G6 Intel
- H3C UniServer R5500 G5 HYGON
- H3C UniServer R4700 G5
- H3C UniServer R4900 G3
- H3C UniServer R4950 G5 Rome
- H3C UniServer R5500 G7 Hygon
- H3C UniServer B5700 G3
- H3C UniServer R5300 G6
- H3C UniServer E3200 G3
- H3C UniServer R8900 G3
- H3C UniServer R4300 G6
- H3C UniServer R2700 G3
- H3C UniServer R4930LC G5 H3
- H3C UniServer R5500 G5 AMD
- H3C UniServer R4950 G6
- H3C UniServer R4700LC G5
- H3C UniServer R5500LC G5 Intel
- H3C UniServer B7800 G3
- H3C UniServer R4900LE G6 Ultra
- H3C UniServer R5500 G5 Intel
- H3C UniServer R4330 G5 H3
- H3C UniServer R6900 G3
- H3C UniServer R4700LE G6
- H3C UniServer R4950 G5
- H3C UniServer B5800 G3
- H3C UniServer R5330 G7
- H3C UniServer R5500 G6 AMD
- H3C UniServer R4330 G5
- H3C UniServer R6700 G3
- H3C UniServer R5300 G5
- H3C UniServer R4930 G5 H3
- H3C UniServer R4300 G5
- H3C UniServer R6700 G6
- H3C UniServer R4900LC G5
- H3C UniServer R4930 G5
- H3C UniServer R4700 G3
- H3C UniServer B5700 G6
- H3C UniServer R4700 G6
- H3C UniServer B5700 G5
OS
linux
OS Subclass
CAS-E0783
New Functions
1.None.
View Details
|
R4500 G6 4U 15LFF CPLD | V002 | Firmware | N/A | N/A | 2024/8/20 |
|
|
Version
V002
File Name
H3C UniServer R4500 G6 4U 15LFF CPLD V002 Release Notes.pdf(359.83 KB) RS3B15LF01002.bin.zip(50.18 KB)
Description
This software is used to upgrade the 15LFF CPLD version on the R4500 G6 server.
Problems Solved
Products
- Obtained from the release notes
OS
N/A
OS Subclass
N/A
New Functions
View Details
|
B5700 G5 HDM | 3.48 | Firmware | N/A | N/A | 2024/8/20 |
|
|
Version
3.48
File Name
H3C HDM-3.48 Release Notes.pdf(2.15 MB) G5-HDM-3.48_signed.bin.zip(40.13 MB) H3C HDM IPMI Basics Command Reference_V3.47.pdf(3.37 MB) H3C HDM Redfish API Reference_V3.47.pdf(5.41 MB) mib.zip(1.27 MB)
Description
This software is used to upgrade the HDM version of the B5700 G5 server
Problems Solved
Resolved problems in HDM-3.48
Symptom: The B5700 G5 failed to interconnect with the OM module after historical passwords are disabled on BMC for the B5700 G5. Condition: This symptom might occur if historical passwords are disabled on HDM for the B5700 G5.
Symptom: A service alarm occurs on the server due to I/O delays. Condition: This symptom might occur if the LSI storage controller is configured and CC inspection is enabled in an in-band manner.
Symptom: You can create a logical drive in RAID 10 for the LSI-9460-8i storage controller through the Web interface. If the number of RAID arrays exceeds eight, the creation might fail, causing the storage process to get stuck. Condition: This symptom might occur if you create a logical drive in RAID 10 for the LSI-9460-8i storage controller through the Web interface, but the number of RAID arrays exceeds eight.
Symptom: The Redfish library failed to use the HDM interface to obtain part of performance indexes incorrectly. Condition: This symptom might occur if the Redfish library uses the HDM interface to obtain power output consumption.
Products
- H3C UniServer B5700 G5
OS
N/A
OS Subclass
N/A
New Functions
HDM-3.48HDM-3.48 added support of the following hardware options for the R4900 G5: QLE2694-SR-AK 16G FC-HBA ScaleFlux CSD 3320 3.84TSSD HDM-3.48 added support of the following hardware options for the R4950 G5: Hanbo GPU VG1000-32G-LP
View Details
|
B5800 G5 HDM | 3.48 | Firmware | N/A | N/A | 2024/8/20 |
|
|
Version
3.48
File Name
H3C HDM-3.48 Release Notes.pdf(2.15 MB) G5-HDM-3.48_signed.bin.zip(40.13 MB) H3C HDM IPMI Basics Command Reference_V3.47.pdf(3.37 MB) H3C HDM Redfish API Reference_V3.47.pdf(5.41 MB) mib.zip(1.27 MB)
Description
This software is used to upgrade the HDM version of the B5800 G5 server
Problems Solved
Resolved problems in HDM-3.48
Symptom: The B5700 G5 failed to interconnect with the OM module after historical passwords are disabled on BMC for the B5700 G5. Condition: This symptom might occur if historical passwords are disabled on HDM for the B5700 G5.
Symptom: A service alarm occurs on the server due to I/O delays. Condition: This symptom might occur if the LSI storage controller is configured and CC inspection is enabled in an in-band manner.
Symptom: You can create a logical drive in RAID 10 for the LSI-9460-8i storage controller through the Web interface. If the number of RAID arrays exceeds eight, the creation might fail, causing the storage process to get stuck. Condition: This symptom might occur if you create a logical drive in RAID 10 for the LSI-9460-8i storage controller through the Web interface, but the number of RAID arrays exceeds eight.
Symptom: The Redfish library failed to use the HDM interface to obtain part of performance indexes incorrectly. Condition: This symptom might occur if the Redfish library uses the HDM interface to obtain power output consumption.
Products
- H3C UniServer B5700 G5
OS
N/A
OS Subclass
N/A
New Functions
HDM-3.48HDM-3.48 added support of the following hardware options for the R4900 G5: QLE2694-SR-AK 16G FC-HBA ScaleFlux CSD 3320 3.84TSSD HDM-3.48 added support of the following hardware options for the R4950 G5: Hanbo GPU VG1000-32G-LP
View Details
|
B7800 G5 HDM | 3.48 | Firmware | N/A | N/A | 2024/8/20 |
|
|
Version
3.48
File Name
H3C HDM-3.48 Release Notes.pdf(2.15 MB) G5-HDM-3.48_signed.bin.zip(40.13 MB) H3C HDM IPMI Basics Command Reference_V3.47.pdf(3.37 MB) H3C HDM Redfish API Reference_V3.47.pdf(5.41 MB) mib.zip(1.27 MB)
Description
This software is used to upgrade the HDM version of the B7800 G5 server
Problems Solved
Resolved problems in HDM-3.48
Symptom: The B5700 G5 failed to interconnect with the OM module after historical passwords are disabled on BMC for the B5700 G5. Condition: This symptom might occur if historical passwords are disabled on HDM for the B5700 G5.
Symptom: A service alarm occurs on the server due to I/O delays. Condition: This symptom might occur if the LSI storage controller is configured and CC inspection is enabled in an in-band manner.
Symptom: You can create a logical drive in RAID 10 for the LSI-9460-8i storage controller through the Web interface. If the number of RAID arrays exceeds eight, the creation might fail, causing the storage process to get stuck. Condition: This symptom might occur if you create a logical drive in RAID 10 for the LSI-9460-8i storage controller through the Web interface, but the number of RAID arrays exceeds eight.
Symptom: The Redfish library failed to use the HDM interface to obtain part of performance indexes incorrectly. Condition: This symptom might occur if the Redfish library uses the HDM interface to obtain power output consumption.
Products
- H3C UniServer B5700 G5
OS
N/A
OS Subclass
N/A
New Functions
HDM-3.48HDM-3.48 added support of the following hardware options for the R4900 G5: QLE2694-SR-AK 16G FC-HBA ScaleFlux CSD 3320 3.84TSSD HDM-3.48 added support of the following hardware options for the R4950 G5: Hanbo GPU VG1000-32G-LP
View Details
|
R4300 G6 HDM | 1.72 | Firmware | N/A | N/A | 2024/8/20 |
|
|
Version
1.72
File Name
H3C HDM2-1.72 Release Notes.pdf(1.49 MB) H3C HDM2 IPMI Basics Command Reference_V1.13.pdf(3.27 MB) H3C HDM2 Redfish API Reference_V1.13.pdf(7.97 MB) HDM2_1.72_signed.bin.zip(52.98 MB) mib.zip(1.79 MB)
Description
This software is used to upgrade the HDM version of the R4300 G6 server
Problems Solved
Resolved problems in HDM2-1.72
Symptom: When you send a configuration subscription request through Redfish, adding a path to the end of the server IP port will cause a request error. Condition: This symptom might occur if you add a path to the end of the server IP when sending a configuration subscription request through Redfish.
Symptom: For the R4700 G6 server's Trimode configuration, if you first connect four onboard SATA + 4NVME to ensure the Trimode environment displays correctly, and then replace the last four NVME with SATA, the newly replaced SATA drives will report "disk missing" after a period. The DC then also reports "disk missing." Condition: This symptom might occur if you first configure four onboard SATA+4NVMe and then replace 4NVMe with 4SATA.
Symptom: When the R4950 G6 server is configured with a BCM957508-P2100G network adapter (firmware version 222.1.68.0), HDM is unable to obtain the temperature of the network adapter. Condition: This symptom might occur when the R4950 G6 server is configured with a BCM957508-P2100G network adapter (firmware version 222.1.68.0).
Products
- H3C UniServer R4900 G6 Ultra
- H3C UniServer R4700 G6
- H3C UniServer R4300 G6
- H3C UniServer R4700LE G6
- H3C UniServer R4900 G6
- H3C UniServer R4900LE G6
OS
N/A
OS Subclass
N/A
New Functions
View Details
|
R4900 G6 Ultra HDM | 1.73.01 | Firmware | N/A | N/A | 2024/8/16 |
|
|
Version
1.73.01
File Name
H3C HDM2-1.73.01 Release Notes.pdf(1.50 MB) H3C HDM2 IPMI Basics Command Reference_V1.14.pdf(4.19 MB) H3C HDM2 Redfish API Reference_V1.14.pdf(8.65 MB) HDM2_1.73.01_signed.bin.zip(52.99 MB) mib.zip(2.37 MB)
Description
This software is used to upgrade the HDM version of the R4900 G6 Ultra server
Problems Solved
Resolved problems in HDM2-1.73.01None.
Products
- H3C UniServer R4700LE G6
- H3C UniServer R4900 G6
- H3C UniServer R4900 G6 Ultra
- H3C UniServer R4900LE G6
- H3C UniServer R4700 G6
- H3C UniServer R4300 G6
- H3C UniServer R6700 G6
- H3C UniServer R6900 G6
OS
N/A
OS Subclass
N/A
New Functions
View Details
|
R4700 G6 HDM | 1.73.01 | Firmware | N/A | N/A | 2024/8/16 |
|
|
Version
1.73.01
File Name
H3C HDM2-1.73.01 Release Notes.pdf(1.50 MB) H3C HDM2 IPMI Basics Command Reference_V1.14.pdf(4.19 MB) H3C HDM2 Redfish API Reference_V1.14.pdf(8.65 MB) HDM2_1.73.01_signed.bin.zip(52.99 MB) mib.zip(2.37 MB)
Description
This software is used to upgrade the HDM version of the R4700 G6 server
Problems Solved
Resolved problems in HDM2-1.73.01None.
Products
- H3C UniServer R4900 G6
- H3C UniServer R6900 G6
- H3C UniServer R4900 G6 Ultra
- H3C UniServer R6700 G6
- H3C UniServer R4700 G6
- H3C UniServer R4900LE G6
- H3C UniServer R4300 G6
- H3C UniServer R4700LE G6
OS
N/A
OS Subclass
N/A
New Functions
View Details
|
R6900 G6 HDM | 1.73.01 | Firmware | N/A | N/A | 2024/8/16 |
|
|
Version
1.73.01
File Name
H3C HDM2-1.73.01 Release Notes.pdf(1.50 MB) H3C HDM2 IPMI Basics Command Reference_V1.14.pdf(4.19 MB) H3C HDM2 Redfish API Reference_V1.14.pdf(8.65 MB) HDM2_1.73.01_signed.bin.zip(52.99 MB) mib.zip(2.37 MB)
Description
This software is used to upgrade the HDM version of the R6900 G6 server
Problems Solved
Resolved problems in HDM2-1.73.01None.
Products
- H3C UniServer R4700 G6
- H3C UniServer R6700 G6
- H3C UniServer R4700LE G6
- H3C UniServer R4900 G6 Ultra
- H3C UniServer R4900 G6
- H3C UniServer R4300 G6
- H3C UniServer R6900 G6
- H3C UniServer R4900LE G6
OS
N/A
OS Subclass
N/A
New Functions
View Details
|
R4900LE G6 HDM | 1.73.01 | Firmware | N/A | N/A | 2024/8/16 |
|
|
Version
1.73.01
File Name
H3C HDM2-1.73.01 Release Notes.pdf(1.50 MB) H3C HDM2 IPMI Basics Command Reference_V1.14.pdf(4.19 MB) H3C HDM2 Redfish API Reference_V1.14.pdf(8.65 MB) HDM2_1.73.01_signed.bin.zip(52.99 MB) mib.zip(2.37 MB)
Description
This software is used to upgrade the HDM version of the R4900LE G6 server
Problems Solved
Resolved problems in HDM2-1.73.01None.
Products
- H3C UniServer R4700 G6
- H3C UniServer R4900LE G6
- H3C UniServer R4300 G6
- H3C UniServer R6900 G6
- H3C UniServer R4900 G6
- H3C UniServer R4700LE G6
- H3C UniServer R6700 G6
- H3C UniServer R4900 G6 Ultra
OS
N/A
OS Subclass
N/A
New Functions
View Details
|