Version:3.48(2024/8/20)
Upgrade recommendations
Optional upgrade
Problems Solved
Resolved problems in HDM-3.48
Symptom: The B5700 G5 failed to interconnect with the OM module after historical passwords are disabled on BMC for the B5700 G5.
Condition: This symptom might occur if historical passwords are disabled on HDM for the B5700 G5.
Symptom: A service alarm occurs on the server due to I/O delays.
Condition: This symptom might occur if the LSI storage controller is configured and CC inspection is enabled in an in-band manner.
Symptom: You can create a logical drive in RAID 10 for the LSI-9460-8i storage controller through the Web interface. If the number of RAID arrays exceeds eight, the creation might fail, causing the storage process to get stuck.
Condition: This symptom might occur if you create a logical drive in RAID 10 for the LSI-9460-8i storage controller through the Web interface, but the number of RAID arrays exceeds eight.
Symptom: The Redfish library failed to use the HDM interface to obtain part of performance indexes incorrectly.
Condition: This symptom might occur if the Redfish library uses the HDM interface to obtain power output consumption.
New Functions
HDM-3.48
HDM-3.48 added support of the following hardware options for the R4900 G5:
QLE2694-SR-AK 16G FC-HBA
ScaleFlux CSD 3320 3.84TSSD
HDM-3.48 added support of the following hardware options for the R4950 G5:
Hanbo GPU VG1000-32G-LP
Upgrade recommendations
Optional upgrade
Problems Solved
Resolved problems in HDM-3.41
202309262006
Symptom: When the password validity is set on the server, hREST cannot obtain the related information.
Condition: This symptom might occur when the password validity is set on the server.
202310070370
Symptom: When drives are installed to the R4900 G5 with the 8SFF UniBay drive backplane, the drive locations displayed on HDM do not match the actual configurations.
Condition: This symptom might occur if the R4900 G5 is installed with 8SFF UniBay drive backplane.
202310180364
Symptom: When an ADDDC error occurs, the server does not report the corresponding log information.
Condition: This symptom might occur if an ADDDC error occurs on the server.
202309260780
Symptom: When the server is installed with a PCIe module that has MB in its name and an error occurs on the PCIe module, MCA suggests replacing the module. However, HDM shows a critical alarm on the system board.
Condition: This symptom might occur if the server is installed with a PCIe module that has MB in its name and an error occurs on the PCIe module.
202310172253
Symptom: An SEL alarm of system detected the absence of a DIMM was mistakenly reported on the R5500 G5.
Condition: This symptom might occur if a G5 Intel sever is installed with non-certified DIMMs and is restarted.
New Functions
HDM-3.41
HDM-3.41 added support of the following hardware options for the R4900 G5:
Solidigm P5520 15.36T drive
Great Wall 2700W power supply
IVA-CP24-VA
HDM-3.40 added support of the following hardware options for the R4950 G5:
Configuration only with the rear 4SFF UniBay drive backplane
HDM-3.40 added support of the following hardware options for the R5300 G5:
Iluvatar V100 (MR) GPU
Upgrade recommendations
Optional upgrade
Problems Solved
Resolved problems in HDM-3.39
202307180160
Symptom: Ucenter reports Unknown state of logical drives when the R4900 G3 is installed with LSI RAID controllers.
Condition: This symptom might occur when the R4900 G3 is installed with LSI RAID controllers.
Symptom: The physical view tab of the storage management page displays additional drive presence information when the R4900 G3 uses the 24 NVMe drive configuration.
Condition: This symptom might occur when the R4900 G3 uses the 24 NVMe drive configuration.
202307120329
Symptom: When the R4300 G5 is installed with drives of multiple types, it takes a long time for SNMP WALK to obtain drive information.
Condition: This symptom might occur when the R4300 G5 is installed with drives of multiple types.
202308070270
Symptom: When a G3/G5 server is installed with two LSI HBA modules, such as 9500-8i+ 9300-8i, the system reports Drive Fault alarms mistakenly.
Condition: This symptom might occur when a G3/G5 server is installed with two LSI HBA modules, such as 9500-8i+ 9300-8i.
202307240022
Symptom: When the R5500K installed with an OCP network restarts after a stress test, the system reports OCP overtemperature alarms in bulk.
Condition: This symptom might occur if you install an OCP network adapter on the R5500K, perform a stress test, and restart the DC power.
202307192176
Symptom: Heat dissipation issues occur on the R5500 G5 installed with a 332A network adapter.
Condition: This symptom might occur on the R5500 G5 when a 332A intelligent network adapter is installed and the system enters FAKE S5.
New Functions
HDM-3-39
HDM-3.39 added support of the following hardware options for the R5300 G5:
Nvidia H800 GPU
Nvidia L40S GPU
RG800 Pro GPU
HDM-3.39 added support of the following hardware options for the R4930 G5 (H3):
GPU-RG800-32GB-FHFL
25SFF drive backplane PCA-BP-25SFF-2U-G5 used together with NVMe drives
HDM-3.39 added support of the following hardware options for the R4950 G5:
UN-RC-2FHFL-R3-2U-G5